Table T4. Measurements and specifications for wireline tools.

Tool string Tool Measurement Sampling interval
(cm)
Approximate vertical
resolution (cm)
Triple combination MGT* Spectral gamma ray   15
HNGS Spectral gamma ray 15 51
APS Porosity 5 and 15 43
HLDT Bulk density 2.5 38
DIT-E Resistivity 15 200/150/76
TAP Temperature 1 per s NA
Tool acceleration 4 per s NA
Pressure 1 per s NA
Formation MicroScanner (FMS)-sonic combination NGT Spectral gamma ray 15 46
GPIT Tool orientation 0.25 and 15 NA
FMS Microresistivity 0.25 0.5
DSI/SDT/LSS/BHC Acoustic velocity 15 107

Notes: All tool and tool string names (except the TAP and MGT tools) are trademarks of Schlumberger. For additional information about tool physics and use, consult IODP–USIO Science Services, LDEO, at iodp.ldeo.columbia.edu/​TOOLS_LABS/​tools.html. See Table T5 for explanations of acronyms used to describe tool strings and tools. * = not included in each logging run. NA = not applicable.