Table T2. Saturating fluid resistivities. (See table note.)
Batch number |
Resistivity (Ωm) | |||||
---|---|---|---|---|---|---|
~0.006 g/L | ~0.06 g/L | ~0.6 g/L | ~6 g/L | ~30 g/L | ~60 g/L | |
1 | 427.4 | 72.46 | 6.068 | 0.9272 | 0.2347 | 0.1233 |
2 | 440.5 | 73.53 | 6.057 | 0.9275 | 0.2353 | 0.1230 |
3 | 432.9 | 72.99 | 6.079 | 0.9273 | 0.2358 | 0.1227 |
4 | 436.7 | 71.94 | 6.079 | 0.9272 | 0.2347 | 0.1227 |
5 | 438.6 | 73.53 | 6.075 | 0.9301 | 0.2353 | 0.1230 |
Note: Deviations from normal resistivity at the given fluid salinity are due to progressive reequilibration between the sample and fluid before measurements are taken.
Previous | Close | Next | Top of page