Table T16. Measurements made by wireline tool strings.

Tool string Tool Measurement Sampling
interval
(cm)
Approximate
vertical
resolution
(cm)
Triple combination HNGS Spectral gamma ray 15 51
APS Porosity 5 and 15 43
HLDS Bulk density 2.5 and 15 46
DLL Resistivity 15 61
TAP Temperature 1 per s NA
Tool acceleration 4 per s NA
Pressure 1 per s NA
EMS Temperature 15 NA
Resistivity    
Formation MicroScanner (FMS)-sonic combination FMS Microresistivity 0.25 0.5
GPIT Tool orientation 0.25 and 15 NA
SGT Total gamma ray 15 NA
DSI Acoustic velocity 15 107
Ultrasonic Borehole Imager UBI Ultrasonic imaging Variable 0.5–2
GPIT Tool orientation 0.25 and 15 NA
SGT Total gamma ray 15  
WST WST Acoustic arrival time NA NA
VSI VSI Acoustic arrival time NA NA

Notes: All tool and tool string names (except the TAP) are trademarks of Schlumberger. For the complete list of acronyms used in the IODP and for additional information about tool physics and use consult IODP Logging Services at iodp.ldeo.columbia.edu/​TOOLS_LABS/​tools.html. See Table T17 for explanation of acronyms used to describe tool string and tools. NA = not applicable.