Table T2. Temperature tool deployments.
Core |
Depth (mbsf) |
Corrected temperature (°C) |
Uncorrected temperature (°C) |
Thermal conductivity (W/[m·K]) |
Calibration correction (°C) |
Temperature tool |
Solution reliability |
---|---|---|---|---|---|---|---|
311-U1325B- | |||||||
4H | 33.5 | 4.44 | 4.44 | 1.1 | 0 | APCT-3 | Excellent |
6H | 52.5 | 6.47 | 6.47 | 1.1 | 0 | APCT-3 | Excellent |
8H | 71.5 | 7.11 | 7.11 | 1.1 | 0 | APCT-3 | Excellent |
19X–20X | 150.2 | 12.66 | 12.66 | 1.1 | 0 | DVTP | Excellent |
311-U1325C- | |||||||
5H–6H | 218.6 | 16.89 | 16.89 | 1.1 | 0 | DVTP | Good |
12H–13H | 275.4 | 18.64 | 18.64 | 1.1 | 0 | DVTP | Very good |
311-U1326C- | |||||||
4H | 30.4 | 4.3 | 4.3 | 1.1 | 0 | APCT-3 | Very good |
311-U1326D- | |||||||
19X | 252.2 | NA† | NA | 1.1 | 0 | DVTP | Poor (heave) |
21X | 271.4 | NA | NA | 1.1 | 0 | DVTP | Fair (heave) |
BOH | 300.0 | NA | NA | 1.1 | 0 | DVTP | Fair (heave) |
311-U1327C- | |||||||
3H | 25.1 | NA | NA | NA | –0.97 | APCT16 | Poor |
5H | 44.1 | 6.6 | 7.6 | 1.1 | –0.97 | APCT16 | Good |
7H | 55.6 | 9.04 | 9.005 | 1.1 | –0.97 | APCT16 | Good |
9H | 74.6 | 10.544 | 11.514 | 1.1 | –0.97 | APCT16 | Excellent |
19X–20X | 161.0 | NA | NA | NA | NA | DVTP | Instrument failed |
25X–26X | 209.0 | 15.1 | 15.1 | 1.1 | 0 | DVTPP3 | Excellent |
34X–35X | 295.0 | NA | NA | NA | NA | DVTPP3 | Poor |
311-U1328B- | |||||||
8H | 37.5 | 5.45 | 6.42 | 1.1 | –0.97 | APCT16 | Good |
10H | 56.5 | 10* | 10 | 1.1 | 0 | APCT-3 | Poor (heave) |
10H–11H | 56.5 | ND | ND | ND | ND | DVTPP3 | No data |
311-U1328C- | |||||||
2H | 75.5 | 7.57 | 8.54 | 1.1 | –0.97 | APCT16 | Good |
3H | 85.0 | 9 | 9 | 1.1 | 0 | APCT-3 | Poor |
6H | 103.5 | 11 | 11 | 1.1 | 0 | APCT-3 | Poor (heave) |
11X–12X | 148.9 | ND | ND | ND | ND | DVTPP3 | No data |
16X–17X | 197.1 | ND | ND | ND | ND | DVTPP3 | No data |
311-U1328E- | |||||||
10P–11Y | 93.0 | 8.47 | 8.47 | 1.1 | 0 | DVTP | Poor (heave) |
11Y–12E | 198.0 | 14.13 | 14.13 | 1.1 | 0 | DVTP | Very good |
311-U1329C- | |||||||
3H | 27.1 | NA | NA | NA | –0.97 | APCT16 | Poor |
5H | 46.1 | 6.6 | 7.6 | 1 | –0.97 | APCT16 | Excellent |
9H | 76.6 | 9.04 | 9.005 | 1 | 0.03 | APCT-3 | Excellent |
11H | 95.6 | 10.544 | 11.514 | 1 | –0.97 | APCT16 | Excellent |
13H | 114.6 | 11.79 | 11.759 | 1 | 0.03 | APCT-3 | Excellent |
311-U1329E- | |||||||
4H | 33.5 | 5.1 | 5.86/6.13 | 1 | –0.97 | APCT16 | Fair |
6H | 64.0 | 7.76 | 8.69 | 1 | –0.97 | APCT16 | Good |
6H–7P | 64.0 | 7.84 | 7.84 | 1 | 0 | DVTP | Good |
BOH | 127.1 | 12.1 | 12.1 | NA | 0 | DVTP | Excellent |
Notes: NA = not applicable, ND = no data. BOH = bottom of hole. APCT-3 = third-generation advanced piston corer temperature too, DVTP = Davis-Villinger Temperature Probe, DVTPP = Davis-Villinger Temperature-Pressure Probe, APCT = advanced piston corer temperature tool, * = measurements severely affected by heave are estimated to nearest degree. † = tool did not stay in the seafloor long enough to obtain in situ temperature using CONEFIT; these data will be modeled postcruise in an attempt to place an upper bound on the in situ temperature.
Previous | Close | Next | Top of page