Previous   |   Close   |   Next

Table T2. Temperature tool deployments.

Core Depth
(mbsf)
Corrected
temperature
(°C)
Uncorrected
temperature
(°C)
Thermal
conductivity
(W/[m·K])
Calibration
correction
(°C)
Temperature
tool
Solution
reliability
311-U1325B-
4H 33.5 4.44 4.44 1.1 0 APCT-3 Excellent
6H 52.5 6.47 6.47 1.1 0 APCT-3 Excellent
8H 71.5 7.11 7.11 1.1 0 APCT-3 Excellent
19X–20X 150.2 12.66 12.66 1.1 0 DVTP Excellent
311-U1325C-
5H–6H 218.6 16.89 16.89 1.1 0 DVTP Good
12H–13H 275.4 18.64 18.64 1.1 0 DVTP Very good
311-U1326C-
4H 30.4 4.3 4.3 1.1 0 APCT-3 Very good
311-U1326D-
19X 252.2 NA NA 1.1 0 DVTP Poor (heave)
21X 271.4 NA NA 1.1 0 DVTP Fair (heave)
BOH 300.0 NA NA 1.1 0 DVTP Fair (heave)
311-U1327C-
3H 25.1 NA NA NA –0.97 APCT16 Poor
5H 44.1 6.6 7.6 1.1 –0.97 APCT16 Good
7H 55.6 9.04 9.005 1.1 –0.97 APCT16 Good
9H 74.6 10.544 11.514 1.1 –0.97 APCT16 Excellent
19X–20X 161.0 NA NA NA NA DVTP Instrument failed
25X–26X 209.0 15.1 15.1 1.1 0 DVTPP3 Excellent
34X–35X 295.0 NA NA NA NA DVTPP3 Poor
311-U1328B-
8H 37.5 5.45 6.42 1.1 –0.97 APCT16 Good
10H 56.5       10* 10 1.1 0 APCT-3 Poor (heave)
10H–11H 56.5 ND ND ND ND DVTPP3 No data
311-U1328C-
2H 75.5 7.57 8.54 1.1 –0.97 APCT16 Good
3H 85.0 9 9 1.1 0 APCT-3 Poor
6H 103.5 11 11 1.1 0 APCT-3 Poor (heave)
11X–12X 148.9 ND ND ND ND DVTPP3 No data
16X–17X 197.1 ND ND ND ND DVTPP3 No data
311-U1328E-
10P–11Y 93.0 8.47 8.47 1.1 0 DVTP Poor (heave)
11Y–12E 198.0 14.13 14.13 1.1 0 DVTP Very good
311-U1329C-
3H 27.1 NA NA NA –0.97 APCT16 Poor
5H 46.1 6.6 7.6 1 –0.97 APCT16 Excellent
9H 76.6 9.04 9.005 1 0.03 APCT-3 Excellent
11H 95.6 10.544 11.514 1 –0.97 APCT16 Excellent
13H 114.6 11.79 11.759 1 0.03 APCT-3 Excellent
311-U1329E-
4H 33.5 5.1 5.86/6.13 1 –0.97 APCT16 Fair
6H 64.0 7.76 8.69 1 –0.97 APCT16 Good
6H–7P 64.0 7.84 7.84 1 0 DVTP Good
BOH 127.1 12.1 12.1 NA 0 DVTP Excellent

Notes: NA = not applicable, ND = no data. BOH = bottom of hole. APCT-3 = third-generation advanced piston corer temperature too, DVTP = Davis-Villinger Temperature Probe, DVTPP = Davis-Villinger Temperature-Pressure Probe, APCT = advanced piston corer temperature tool, * = measurements severely affected by heave are estimated to nearest degree. † = tool did not stay in the seafloor long enough to obtain in situ temperature using CONEFIT; these data will be modeled postcruise in an attempt to place an upper bound on the in situ temperature.

Previous   |   Close   |   Next  |   Top of page