Previous   |   Close   |   Next

Table T17. Summary of pressure coring operations at Site U1326.

Core Core-top
depth
(mbsf)
Length
recovered
(cm)*
Length
curated
(cm)
Pressure at
core depth
(MPa)
Pressure recovered
(MPa)
Comments
Logged Gauge
311-U1326C-
11Y 82.7 15 15 19.2 17.5 17.5 Sand in bottom-hole assembly
12P 83.7 35–40 27 19.2 3.4 3.4 Normal operation
13E 85.7 0 0 19.2 0 Reversal of motor unscrewed joints and left bit in hole

Notes: Water depth at Hole U1326C is 1828 mbsl. P = Pressure Core Sampler (PCS), Y = Fugro Percussion Corer (FPC), E = HYACE Rotary Corer (HRC). * = based on X-ray imaging and gamma ray density profiling prior to degassing. † = last pressure recorded before data logger disconnected from corer autoclave. Temperature 2°–4°C unless otherwise noted. ‡ = pressure measured when autoclave pressure transducer connected to computer (PCS cores) or external gauge (PCS, FPC, HRC cores). Pressure measured at 7°C unless otherwise noted. — = no data.

Previous   |   Close   |   Next  |   Top of page