Table T17. Summary of pressure coring operations at Site U1326.
Core |
Core-top depth (mbsf) |
Length recovered (cm)* |
Length curated (cm) |
Pressure at core depth (MPa) |
Pressure recovered (MPa) |
Comments | |
---|---|---|---|---|---|---|---|
Logged† | Gauge‡ | ||||||
311-U1326C- | |||||||
11Y | 82.7 | 15 | 15 | 19.2 | 17.5 | 17.5 | Sand in bottom-hole assembly |
12P | 83.7 | 35–40 | 27 | 19.2 | 3.4 | 3.4 | Normal operation |
13E | 85.7 | 0 | 0 | 19.2 | 0 | — | Reversal of motor unscrewed joints and left bit in hole |
Notes: Water depth at Hole U1326C is 1828 mbsl. P = Pressure Core Sampler (PCS), Y = Fugro Percussion Corer (FPC), E = HYACE Rotary Corer (HRC). * = based on X-ray imaging and gamma ray density profiling prior to degassing. † = last pressure recorded before data logger disconnected from corer autoclave. Temperature 2°–4°C unless otherwise noted. ‡ = pressure measured when autoclave pressure transducer connected to computer (PCS cores) or external gauge (PCS, FPC, HRC cores). Pressure measured at 7°C unless otherwise noted. — = no data.
Previous | Close | Next | Top of page