Previous   |   Close   |   Next

Table T19. In situ temperature, Holes U1328B, U1328C, and U1328E.

Core Depth
(mbsf)
Temperature (°C) Thermal
conductivity
(W/[m·K])
Calibration
correction
(°)
Temperature
tool
Solution
reliability
Corrected Uncorrected
311-U1328B-
8H 37.5 5.45 6.42 1.1 –0.97 APCT16 Good
10H 56.5 10* 10 1.1 0 APCT-3 Poor (heave)
10H–11H 56.5 ND ND ND ND DVTPP3 No data
311-U1328C-
2H 75.5 7.57 8.54 1.1 –0.97 APCT16 Good
3H 85.0 9 9 1.1 0 APCT-3 Poor
6H 103.5 11 11 1.1 0 APCT-3 Poor (heave)
11X–12X 148.9 ND ND ND ND DVTPP3 No data
16X–17X 197.1 ND ND ND ND DVTPP3 No data
311-U1328E-
10P–11Y 93.0 8.47 8.47 1.1 0 DVTP Poor (heave)
11Y–12E 198.0 14.13 14.13 1.1 0 DVTP Very good

Notes: * = measurements severely affected by heave are estimated to only the nearest degree. ND = not determined. APCT = advanced piston corer temperature tool, APCT-3 = third-generation advanced piston corer temperature tool, DVTPP = Davis-Villinger Temperature-Pressure Probe, DVTP = Davis-Villinger Temperature Probe.