Table AT9. Permeability testing results, Sample 315-C0001H-7R-3, 21–38 cm, vertical.
Effective
stress MPa (psi) |
Test run |
Volumetric flow rate (cm3/min) |
Discharge velocity (cm/s) |
Head loss (cm) |
Hydraulic gradient |
Hydraulic conductivity (cm/s) |
Intrinsic permeability (m2) |
---|---|---|---|---|---|---|---|
0.03 (5) | 1 | –0.00050 | –6.98E–07 | –180 | –40.9 | 1.71E–08 | 1.69E–17 |
2 | –0.00025 | –3.49E–07 | –120 | –27.3 | 1.28E–08 | 1.27E–17 | |
3 | 0.00025 | 3.49E–07 | 99 | 22.5 | 1.55E–08 | 1.54E–17 | |
4 | 0.00050 | 6.98E–07 | 211 | 48.0 | 1.46E–08 | 1.44E–17 | |
Average:
|
1.50E–08 | 1.49E–17 | |||||
0.14 (20) | 1 | –0.00050 | –6.98E–07 | –250 | –56.8 | 1.23E–08 | 1.22E–17 |
2 | –0.00025 | –3.49E–07 | –135 | –30.7 | 1.14E–08 | 1.13E–17 | |
3 | 0.00025 | 3.49E–07 | 140 | 31.8 | 1.10E–08 | 1.09E–17 | |
4 | 0.00050 | 6.98E–07 | 270 | 61.4 | 1.14E–08 | 1.13E–17 | |
Average:
|
1.15E–08 | 1.14E–17 | |||||
0.28 (40) | 1 | –0.00050 | –6.98E–07 | –250 | –56.8 | 1.23E–08 | 1.22E–17 |
2 | –0.00025 | –3.49E–07 | –140 | –31.8 | 1.10E–08 | 1.09E–17 | |
3 | 0.00025 | 3.49E–07 | 155 | 35.2 | 9.91E–09 | 9.83E–18 | |
4 | 0.00050 | 6.98E–07 | 300 | 68.2 | 1.02E–08 | 1.02E–17 | |
Average:
|
1.08E–08 | 1.08E–17 | |||||
0.41 (60) | 1 | –0.00050 | –6.98E–07 | –270 | –61.4 | 1.14E–08 | 1.13E–17 |
2 | –0.00025 | –3.49E–07 | –145 | –33.0 | 1.06E–08 | 1.05E–17 | |
3 | 0.00025 | 3.49E–07 | 155 | 35.2 | 9.91E–09 | 9.83E–18 | |
4 | 0.00050 | 6.98E–07 | 285 | 64.8 | 1.08E–08 | 1.07E–17 | |
Average:
|
1.07E–08 | 1.06E–17 | |||||
0.55 (80) | 1 | –0.00050 | –6.98E–07 | –282 | –64.1 | 1.09E–08 | 1.08E–17 |
2 | –0.00025 | –3.49E–07 | –152 | –34.5 | 1.01E–08 | 1.00E–17 | |
3 | 0.00025 | 3.49E–07 | 146 | 33.2 | 1.05E–08 | 1.04E–17 | |
4 | 0.00050 | 6.98E–07 | 285 | 64.8 | 1.08E–08 | 1.07E–17 | |
Average:
|
1.06E–08 | 1.05E–17 |
Positive values of volumetric flow rate and discharge velocity indicate bottom to top flow through the specimen; negative values indicate top to bottom flow.