Table T14. Downhole measurements made by wireline tool strings, Expedition 335.

Tool string
Tool
Measurement
Sampling interval
(cm)
Vertical resolution
(cm)
Triple combo LEH-MT Temperature 15 NA
EDTC Total gamma ray 5 and 15 30
APS Porosity 5 and 15 36
HLDS Bulk density 2.5 and 15 38
HRLA Resistivity 15 30
MTT Temperature 15 NA
GPIT Tool orientation and acceleration 15 NA

For definitions of tool acronyms, see Table T15. All tool and tool string names except the MTT are trademarks of Schlumberger. Sampling interval based on optimal logging speed. Acoustic imaging approximate vertical resolution is at 500 kHz. NA = not applicable.