Table T2. Permeability test results, Hole C0020A.
Measurement | Unit | 337-C0020A-15R-1, 56–59 cm | 337-C0020A-15R-4, 72.5–75.5 cm | ||
---|---|---|---|---|---|
Confining pressure | MPa | 40 | 50 | 40 | 50 |
Time | h | 2.17 | 14.64 | 2.47 | 14.53 |
Volume change | cm3 | 0.20077322 | 0.06974 | 0.20154762 | 0.07035255 |
Volumetric flow rate | cm3/h | 0.092545914 | 0.004762215 | 0.093021978 | 0.004842623 |
Pressure difference | Mpa | 0.5 | 0.5 | 0.5 | 0.5 |
Difference of water head | cm | 4901.96 | 4901.96 | 4901.96 | 4901.96 |
Length of the specimen | cm | 2.01 | 2.01 | 1.80 | 1.80 |
Area of the specimen | cm2 | 32.31 | 32.31 | 30.96 | 30.96 |
Hydraulic gradient | ‰ | 2438.79 | 2438.79 | 2723.31 | 2723.31 |
Flow velocity | cm/h | 2.86E–03 | 1.47E–04 | 3.00E–03 | 1.56E–04 |
Coefficient of permeability | cm/h | 1.17E–06 | 6.04E–08 | 1.10E–06 | 5.74E–08 |
cm/s | 3.26E–10 | 1.68E–11 | 3.06E–10 | 1.60E–11 | |
Intrinsic permeability | m2 | 3.20E–17 | 1.68E–18 | 3.06E–17 | 1.60E–18 |
Previous | Close | Next | Top of page