Table T17. Electrical resistivity testing of the Wenner probe between correct and incorrect pin configuration, Hole C0022B.

Core, section,
interval (cm)
Electrical impedance
of sample at 2 kHz
(Ω)
Impedance phase
angle of sample
(°)
Electrical impedance
of seawater at 2 kHz (Ω)
Impedance phase
angle of seawater
(°)
Resistivity
(Ωm)
Pin
configuration
Ratio resistivity
wrong/good
configuration
338-C0022B-
10T-5, 14 10.96 –3.65 6.80 0.44 0.44 Correct 0.97
10T-5, 14 11.05 –12.43 6.53 2.25 0.46 Incorrect
10T-5, 87 14.24 9.59 6.80 0.44 0.57 Correct 1.17
10T-5, 87 12.09 16.99 6.53 2.25 0.49 Incorrect
11T-1, 42 4.09 15.03 6.80 0.44 0.16 Correct 0.45
11T-1, 42 8.44 –0.37 6.53 2.25 0.36 Incorrect
11T-CC, 2 14.99 –0.75 7.49 0.65 0.55 Correct 0.94
11T-CC, 2 12.30 –7.98 5.75 0.21 0.58 Incorrect