Table T21. Thermal conductivity results, Hole U1410A.
Core, section, interval (cm) |
Depth (mbsf) |
Thermal conductivity (W/[m·K]) |
Heating power (W/m) |
||
---|---|---|---|---|---|
Mean | Standard deviation | Observation | |||
342-U1410A- | |||||
1H-3W, 75 | 3.01 | 0.993 | 2.41E–02 | 0.959* | 1.612 |
1H-3W, 75 | 3.01 | 1.009* | 1.612 | ||
1H-3W, 75 | 3.01 | 1.011* | 1.612 | ||
2H-3W, 75 | 11.51 | 0.896 | 3.52E–02 | 0.846* | 1.612 |
2H-3W, 75 | 11.51 | 0.921 | 1.612 | ||
2H-3W, 75 | 11.51 | 0.920 | 1.612 | ||
3H-3W, 75 | 21.01 | 0.971 | 5.50E–03 | 0.970 | 1.612 |
3H-3W, 75 | 21.01 | 0.965* | 1.612 | ||
3H-3W, 75 | 21.01 | 0.978 | 1.612 | ||
4H-3W, 75 | 30.51 | 1.411 | 2.24E–02 | 1.380 | 1.612 |
4H-3W, 75 | 30.51 | 1.428 | 1.612 | ||
4H-3W, 75 | 30.51 | 1.426 | 1.612 | ||
5H-3W, 75 | 40.01 | 1.130 | 1.61E–02 | 1.107 | 1.612 |
5H-3W, 75 | 40.01 | 1.144* | 1.612 | ||
5H-3W, 75 | 40.01 | 1.138* | 1.612 | ||
6H-3W, 75 | 49.51 | 1.060 | 3.67E–02 | 1.008* | 1.612 |
6H-3W, 75 | 49.51 | 1.090 | 1.612 | ||
6H-3W, 75 | 49.51 | 1.081 | 1.612 | ||
7H-3W, 31 | 59.05 | 1.179 | 1.45E–02 | 1.160 | 1.612 |
7H-3W, 31 | 59.05 | 1.183* | 1.612 | ||
7H-3W, 31 | 59.05 | 1.195 | 1.612 | ||
8H-3A, 75 | 68.51 | 1.156 | 1.67E–02 | 1.132 | 1.612 |
8H-3A, 75 | 68.51 | 1.170* | 1.612 | ||
8H-3A, 75 | 68.51 | 1.165* | 1.612 | ||
9H-3A, 30 | 78.00 | 1.183 | 8.80E–03 | 1.171 | 1.612 |
9H-3A, 30 | 78.00 | 1.191* | 1.612 | ||
9H-3A, 30 | 78.00 | 1.187 | 1.612 | ||
10H-3A, 75 | 85.69 | 1.199 | 2.01E–02 | 1.173* | 1.612 |
10H-3A, 75 | 85.69 | 1.202* | 1.612 | ||
10H-3A, 75 | 85.69 | 1.222* | 1.612 | ||
11H-3A, 75 | 97.01 | 1.123 | 5.62E–02 | 1.151 | 1.612 |
11H-3A, 75 | 97.01 | 1.174 | 1.612 | ||
11H-3A, 75 | 97.01 | 1.045 | 1.612 | ||
12H-3A, 75 | 106.51 | 1.155 | 7.70E–03 | 1.154 | 1.612 |
12H-3A, 75 | 106.51 | 1.164* | 1.612 | ||
12H-3A, 75 | 106.51 | 1.145 | 1.612 | ||
13H-3A, 75 | 114.98 | 1.150 | 3.70E–03 | 1.145* | 1.612 |
13H-3A, 75 | 114.98 | 1.154* | 1.612 | ||
13H-3A, 75 | 114.98 | 1.150* | 1.612 | ||
14H-3A, 75 | 125.51 | 1.138 | 1.70E–02 | 1.114* | 1.612 |
14H-3A, 75 | 125.51 | 1.151* | 1.612 | ||
14H-3A, 75 | 125.51 | 1.149 | 1.612 | ||
15H-3A, 75 | 134.99 | 1.144 | 1.59E–02 | 1.151 | 1.612 |
15H-3A, 75 | 134.99 | 1.159 | 1.612 | ||
15H-3A, 75 | 134.99 | 1.122* | 1.612 | ||
16H-3W, 75 | 144.51 | 1.166 | 7.80E–03 | 1.155 | 1.612 |
16H-3W, 75 | 144.51 | 1.174* | 1.612 | ||
16H-3W, 75 | 144.51 | 1.168* | 1.612 | ||
17X-3W, 75 | 154.01 | 1.135 | 2.20E–02 | 1.109* | 1.612 |
17X-3W, 75 | 154.01 | 1.163 | 1.612 | ||
17X-3W, 75 | 154.01 | 1.132* | 1.612 | ||
18X-3W, 75 | 163.61 | 1.198 | 4.70E–03 | 1.192 | 1.612 |
18X-3W, 75 | 163.61 | 1.203* | 1.612 | ||
18X-3W, 75 | 163.61 | 1.199* | 1.612 | ||
19X-3W, 75 | 173.21 | 1.182 | 1.14E–02 | 1.176 | 1.612 |
19X-3W, 75 | 173.21 | 1.172* | 1.612 | ||
19X-3W, 75 | 173.21 | 1.198 | 1.612 | ||
20X-3W, 75 | 182.81 | 1.202 | 2.34E–02 | 1.172* | 1.612 |
20X-3W, 75 | 182.81 | 1.229* | 1.612 | ||
20X-3W, 75 | 182.81 | 1.205* | 1.612 | ||
22X-3W, 75 | 202.01 | 1.222 | 1.01E–02 | 1.209 | 1.612 |
22X-3W, 75 | 202.01 | 1.234 | 1.612 | ||
22X-3W, 75 | 202.01 | 1.224 | 1.612 | ||
23X-3A, 75 | 211.51 | 1.431 | 2.37E–02 | 1.400 | 1.612 |
23X-3A, 75 | 211.51 | 1.434* | 1.612 | ||
23X-3A, 75 | 211.51 | 1.458* | 1.612 | ||
24X-3A, 75 | 221.01 | 1.316 | 9.90E–03 | 1.330* | 1.612 |
24X-3A, 75 | 221.01 | 1.312* | 1.612 | ||
24X-3A, 75 | 221.01 | 1.307* | 1.612 | ||
25X-3A, 75 | 230.51 | 1.326 | 1.45E–02 | 1.306* | 1.612 |
25X-3A, 75 | 230.51 | 1.339* | 1.612 | ||
25X-3A, 75 | 230.51 | 1.334* | 1.612 | ||
26X-3A, 75 | 240.11 | 1.387 | 1.53E–02 | 1.381* | 1.612 |
26X-3A, 75 | 240.11 | 1.408* | 1.612 | ||
26X-3A, 75 | 240.11 | 1.372* | 1.612 | ||
27X-3A, 75 | 249.71 | 1.496 | 5.20E–03 | 1.494* | 1.612 |
27X-3A, 75 | 249.71 | 1.503 | 1.612 | ||
27X-3A, 75 | 249.71 | 1.491* | 1.612 |
* = result obtained directly from the TK04 processing software. Other results were generated by the IODP uploader using raw data because they were rejected by the TK04 software. Thermal conductivity mean and standard deviation calculated from thermal conductivity observations. Heating power used to perform the measurement is also listed.
Previous | Close | Next | Top of page