Table T4. Acronyms and units used for wireline logging tools. (See table notes.)
Tool* Output Tool name/Explanation of output Unit
DIT-E
Dual Induction Tool
IDPH Deep induction resistivity Ω·m
IMPH Medium induction resistivity Ω·m
SFLU Spherically focused resistivity Ω·m
FMS
Formation MicroScanner
C1, C2 Orthogonal hole diameter Inch
P1AZ Pad 1 azimuth Degree

Spatially oriented resistivity images of borehole wall
GPIT
General Purpose Inclinometer Tool
DEVI Hole deviation Degree
HAZI Hole azimuth Degree
Fx, Fy, Fz Earth's magnetic field (three orthogonal components) Oersted
Ax, Ay, Az Acceleration (three orthogonal components) m/s2
HLDS
Hostile Environment Litho-Density Sonde
LCAL Caliper (measure of borehole diameter) Inch
HNGS
Hostile Environment Gamma Ray Sonde
HSGR Standard (total) gamma ray gAPI
HCGR Computed gamma ray (HSGR minus uranium contribution) gAPI
HFK Potassium (K) wt%
HTHO Thorium (Th) ppm
HURA Uranium (U) ppm
MSS
Magnetic Susceptibility Sonde
HSUS High-resolution sensor susceptibility SI
LSUS Low-resolution sensor susceptibility SI
LCON Low-resolution sensor conductivity (under development) S/m
TEMP Temperature of MSS electronics °C
ZACC Tool acceleration m/s/s

Notes: * = All tool and tool string names (except the MSS) are trademarks of Schlumberger. For the complete list of acronyms used in the IODP and for additional infomation about tool physics and use consult the IODP Tools and Laboratories section at www.iodp-usio.org/default.html.