Table T8. Sampling and storage protocol for WSTP basement fluid samples.
Lab code | Laboratory | Container | Sample volume | Measurement | Treatment |
---|---|---|---|---|---|
WSTP overflow (~1 L) | |||||
WSO | Shipboard analysis | Few drops | Salinity, total dissolved solids | ||
3 mL | pH, alkalinity | ||||
50 µL | ICr (SO4, Ca, K, Mg) | ||||
0.5 mL | ICP (K, Ca, Mg, Na, Li, B, Sr, Ba, Mn, Fe) | ||||
100 µL | AgNO3 titration (Cl) | ||||
3 mL | Spectrophotometry (SiO2, PO4, NH4+) | ||||
1.5 mL | TOC-5000A (DIC) | Frozen until analysis | |||
WSOB | Shore-based analysis | Acid washed | 100 mL | δD, δ18O, δ13CDIC | 2 mL HgCl2 |
WSOA | Shore-based analysis | Plastic | 100 mL | δ34SSO4, δ34SS2– | ~100 mg Cd acetate |
WSOT | Shore-based analysis | Bottles | 100 mL | 87Sr/86Sr, major and trace elements | 2 mL concentrated TM HNO3 |
WSTP Ti-coil (~14 mL) | |||||
WST | Shipboard analysis | ~100 µL | Salinity, total dissolved solids | ||
~100 µL | ICr (SO4, Ca, K, Mg) | ||||
0.5 mL | ICP (K, Ca, Mg, Na, Li, B, Sr, Ba, Mn, and Fe) | If sample collected >12 mL | |||
WSTB | Shore-based analysis | Glass ampule | 5 mL | δD, δ18O, δ13CDIC | 100 µL HgCl2 |
WSTA | Shore-based analysis | Glass ampule | 2 mL | δ34SSO4, δ34SS2– | 10 mg Cd acetate |
WSTT | Shore-based analysis | Poly tube | 5–6 mL | 87Sr/86Sr, major and trace elements | 100 µL TM HNO3 |
Notes: ICr = ion chromatography, ICP = inductively coupled plasma spectrometry. TM = trace metal grade. TOC = total organic carbon analyzer. DIC = dissolved organic carbon. WSO = water sample overflow, WST = water sampler Ti coil. Suffix for shore-based analysis: B = Banerjee, A = Alt, T = Teagle.
Previous | Close | Next | Top of page