Previous   |   Close   |   Next

Table T18. Summary of pressure coring operations, Site U1327.

Core Core-top
depth
(mbsf)
Length
recovered*
(cm)
Length
curated
(cm)
Pressure at
core depth
(MPa)
Pressure recovered
(MPa)
Comments
Logged Gauge
311-U1327C-
6P 44.1 47 47 13.5 0 Burst disk failed
15P 121.8 98 96 14.3 7.3 Normal operation
24P 197.3 98 100 15.1 6.8 2.0 Normal operation
311-U1327D-
3P 83.0 0 0 13.9 0 No pressure
4E 125.3 110 110 14.3 12.1 12.0 Broken catcher ring prevented transfer of core
6Y 132.0 84 84 14.4 0 Liner imploded; corer over-retracted
10P 155.1 98 92 14.7 7.3 4.1 Normal operation
12E 170.5 114 114 14.8 11.7 12.0 Normal operation; logged in MSCL-P and stored in SC
13Y 203.6 48 48 15.1 2.0 Data logger failed; no pressure/temperature data
14E 217.7 115 115 15.3 12.4 12.5 Normal operation; logged in MSCL-P and stored in SC
17P 246.0 98 98 15.6 6.4 2.0 Normal operation
311-U1327E-
2P 40.0 90 90 13.5 0 No core, no pressure
3P 80.0 98 95 13.9 5.5 0.7 Normal operation
4E 128.0 48 48 14.4 0 Side pressure seal broken

Notes: Water depth at Site U1327 is 1303 mbsl. P = Pressure Core Sampler (PCS), Y = Fugro Percussion Corer (FPC), E = HYACE Rotary Corer (HRC). * = based on X-ray imaging and gamma ray density profiling prior to degassing. † = last pressure recorded before data logger disconnected from corer autoclave. Temperature 2°–4°C unless otherwise noted. ‡ = pressure measured when autoclave pressure transducer connected to computer (PCS cores) or external gauge (PCS, FPC, HRC cores). Pressure measured at 7°C unless otherwise noted. SC = HYACINTH storage chamber, MSCL-P = Geotek pressure multisensor core logger. — = no data.

Previous   |   Close   |   Next  |   Top of page