Close   |    Next

Table T1. Operations summary, Site C0003. (See table notes.)

Hole C0003A
Latitude: 33°13.3982′N
Longitude: 136°42.1382′E
Seafloor (drill pipe measurement from rig floor, m): 2481.5
Distance between rig floor and sea level (m): 28.5
Water depth (drill pipe measurement from sea level, m): 2453
Operation Start Depth
(m LSF)
Drilled
(m LSF)
Comments
Date
(Oct
2007)
Local
time (h)
Top Bottom
Hole C0003A LWD hole 18 2200 0 525.5 533.5 8-1/2 inch LWD (GVR-sonic-SVWD-MWD-APWD-ADN).
ROV survey 20 1145        
Tag seafloor 20 1210        
Spud-in 20 1245        
Drilled depth 21 1200        
Tools stuck and packed-off 21 1000       Packed off at 3015 m DRF after pipe connection at 1000 h. Reamed and worked string between 3015 and 3006 m. Stuck in hole at 3007 m DRF at 1345 h. Failed several attempts for torque up and jar down. Pumped Hi-Vis mud to clean. Backed off while trying to turn and move the pipe at 1445 h.
Fishing and cementing 21 1545        
Preparation 21 1545       Made up free-fall funnel, landed on seafloor, then pulled out drill string to surface and checked the break point of assembly.
1st overshot fishing 22 1405       8-1/8 inch overshot assembly was made up, run in, reentered, washed down, and reamed from 2707 to 2785 m DRF. Attempted 7 times between 0000 and 0745 h on 24 Oct and only one was successful but failed to pull up. Pulled out at 1415 h on 24 Oct.
2nd overshot fishing 24 1405       6-3/4 inch overshot assembly was made up and run again on 25 Oct. Reentry took 10 h and the overshot failed again to catch the stuck LWD assembly. Wireline was rigged up with a 7 m sinker bar for dummy run at 2215 h on 25 Oct. After failing to pass through 2780.5 m at 0145 h on 26 Oct, the dummy tool was retrieved. Sinker bar had unscrewed and dropped off. Overshot assembly was recovered back on deck at 0000 h on 27 Oct.
3rd overshot fishing 27 0000       Made up 8-1/8 inch overshot assembly with 6-5/8 inch spiral grapple and reentered the hole at 0315 h on 28 Oct. Ran into 2774 m DRF and rigged up wireline assembly at 0600 h. Overshot latched the pipe after several attempts but failed to pass below 2788 m by wireline and rigged down. Overshot fishing continued until decision was made to pull out 1200 h of 29 Oct.
Plug and cementing 29 1200       Made up a cement stinger, run in and rigged up cement stand. Cement lines flushed at 0200 h on 30 Oct. First cement job was conducted at 0430 h and second cement job was done at 0730 h. After confirming cement return to the seabed by ROV, cementing assembly was pulled out and drill string was cleaned.

Notes: LSF = LWD depth below seafloor. LWD = logging while drilling, GVR = geoVISION resistivity tool, sonic = sonic while drilling (sonicVISION), SVWD = seismicVISION while drilling, MWD = measurement while drilling, APWD = annular pressure while drilling, ADN = Azimuthal Density Neutron tool (adnVISION). ROV = remotely operated vehicle. DRF = drillers depth below rig floor.

Close   |    Next   |    Top of page