Table AT5. Permeability testing results, Sample 315-C0001F-10H-11, 15–35 cm, vertical.
Effective
stress MPa (psi) |
Test run |
Volumetric flow rate (cm3/min) |
Discharge velocity (cm/s) |
Head loss (cm) |
Hydraulic gradient |
Hydraulic conductivity (cm/s) |
Intrinsic permeability (m2) |
---|---|---|---|---|---|---|---|
0.03 (5) | 1 | 0.002 | 2.52E–06 | 300 | 51.7 | 4.87E–08 | 4.84E–17 |
2 | 0.001 | 1.26E–06 | 160 | 27.6 | 4.57E–08 | 4.53E–17 | |
3 | –0.001 | –1.26E–06 | –150 | –25.9 | 4.86E–08 | 4.83E–17 | |
4 | –0.002 | –2.52E–06 | –280 | –48.3 | 5.22E–08 | 5.18E–17 | |
Average:
|
4.88E–08 | 4.84E–17 | |||||
0.14 (20) | 1 | 0.002 | 2.52E–06 | 350 | 60.3 | 4.18E–08 | 4.15E–17 |
2 | 0.001 | 1.26E–06 | 175 | 30.2 | 4.17E–08 | 4.14E–17 | |
3 | –0.001 | –1.26E–06 | –230 | –39.7 | 3.17E–08 | 3.15E–17 | |
4 | –0.002 | –2.52E–06 | –305 | –52.6 | 4.79E–08 | 4.76E–17 | |
Average:
|
4.08E–08 | 4.05E–17 | |||||
0.28 (40) | 1 | 0.002 | 2.52E–06 | 395 | 68.1 | 3.70E–08 | 3.67E–17 |
2 | –0.001 | –1.26E–06 | –125 | –21.6 | 5.83E–08 | 5.79E–17 | |
3 | 0.001 | 1.26E–06 | 205 | 35.3 | 3.57E–08 | 3.54E–17 | |
4 | –0.002 | –2.52E–06 | –310 | –53.4 | 4.72E–08 | 4.68E–17 | |
Average:
|
4.46E–08 | 4.42E–17 | |||||
0.41 (60) | 1 | 0.002 | 2.52E–06 | 375 | 64.7 | 3.89E–08 | 3.87E–17 |
2 | 0.001 | 1.26E–06 | 195 | 33.6 | 3.75E–08 | 3.72E–17 | |
3 | –0.001 | –1.26E–06 | –180 | –31.0 | 4.06E–08 | 4.03E–17 | |
4 | –0.002 | –2.52E–06 | –335 | –57.8 | 4.36E–08 | 4.33E–17 | |
Average:
|
4.02E–08 | 3.99E–17 | |||||
0.55 (80) | 1 | 0.002 | 2.52E–06 | 385 | 66.4 | 3.80E–08 | 3.77E–17 |
2 | 0.001 | 1.26E–06 | 200 | 34.5 | 3.65E–08 | 3.63E–17 | |
3 | –0.001 | –1.26E–06 | –180 | –31.0 | 4.06E–08 | 4.03E–17 | |
4 | –0.002 | –2.52E–06 | –380 | –65.5 | 3.85E–08 | 3.82E–17 | |
Average:
|
3.84E–08 | 3.81E–17 |
Positive values of volumetric flow rate and discharge velocity indicate bottom to top flow through the specimen; negative values indicate top to bottom flow.
Previous | Close | Next | Top of page