Table AT6. Permeability testing results, Sample 315-C0001F-10H-11, 15–35 cm, horizontal.
Effective
stress MPa (psi) |
Test run |
Volumetric flow rate (cm3/min) |
Discharge velocity (cm/s) |
Head loss (cm) |
Hydraulic gradient |
Hydraulic conductivity (cm/s) |
Intrinsic permeability (m2) |
---|---|---|---|---|---|---|---|
0.03 (5) | 1 | 0.002 | 2.65E–06 | 205 | 34.7 | 7.637E–08 | 7.57E–17 |
2 | 0.001 | 1.33E–06 | 100 | 16.9 | 7.85E–08 | 7.79E–17 | |
3 | –0.001 | –1.33E–06 | –100 | –16.9 | 7.85E–08 | 7.79E–17 | |
4 | –0.002 | –2.65E–06 | –220 | –37.3 | 7.11E–08 | 7.05E–17 | |
Average:
|
7.61E–08 | 7.55E–17 | |||||
0.14 (20) | 1 | 0.002 | 2.65E–06 | 283 | 48.0 | 5.52E–08 | 5.48E–17 |
2 | –0.001 | –1.33E–06 | –145 | –24.6 | 5.41E–08 | 5.37E–17 | |
3 | 0.001 | 1.33E–06 | 150 | 25.4 | 5.23E–08 | 5.19E–17 | |
4 | –0.002 | –2.65E–06 | –260 | –44.1 | 6.01E–08 | 5.97E–17 | |
Average:
|
5.55E–08 | 5.50E–17 | |||||
0.28 (40) | 1 | 0.002 | 2.65E–06 | 305 | 51.7 | 5.13E–08 | 5.09E–17 |
2 | –0.001 | –1.33E–06 | –143 | –24.2 | 5.49E–08 | 5.45E–17 | |
3 | 0.001 | 1.33E–06 | 150 | 25.4 | 5.23E–08 | 5.19E–17 | |
4 | –0.002 | –2.65E–06 | –295 | –50.0 | 5.30E–08 | 5.26E–17 | |
Average:
|
5.29E–08 | 5.25E–17 | |||||
0.41 (60) | 1 | 0.002 | 2.65E–06 | 325 | 55.1 | 4.81E–08 | 4.78E–17 |
2 | 0.001 | 1.33E–06 | 160 | 27.1 | 4.90E–08 | 4.87E–17 | |
3 | –0.001 | –1.33E–06 | –191 | –32.4 | 4.11E–08 | 4.08E–17 | |
4 | –0.002 | –2.65E–06 | –345 | –58.5 | 4.53E–08 | 4.50E–17 | |
Average:
|
4.59E–08 | 4.55E–17 | |||||
0.55 (80) | 1 | 0.002 | 2.65E–06 | 328 | 55.6 | 4.77E–08 | 4.73E–17 |
2 | 0.001 | 1.33E–06 | 197 | 33.4 | 3.98E–08 | 3.95E–17 | |
3 | –0.001 | –1.33E–06 | –178 | –30.2 | 4.41E–08 | 4.38E–17 | |
4 | –0.002 | –2.65E–06 | –380 | –64.4 | 4.11E–08 | 4.08E–17 | |
Average:
|
4.32E–08 | 4.29E–17 |
Positive values of volumetric flow rate and discharge velocity indicate bottom to top flow through the specimen; negative values indicate top to bottom flow.
Previous | Close | Next | Top of page