Table AT7. Permeability testing results, Sample 315-C0001F-15H-2, 25–45 cm, vertical.
Effective
stress MPa (psi) |
Test
run |
Volumetric
flow rate (cm3/min) |
Discharge
velocity (cm/s) |
Head loss
(cm) |
Hydraulic
gradient |
Hydraulic
conductivity (cm/s) |
Intrinsic
permeability (m2) |
---|---|---|---|---|---|---|---|
0.03 (5) | 1 | 0.005 | 7.75E–06 | 200 | 41.7 | 1.86E–07 | 1.85E–16 |
2 | 0.002 | 3.10E–06 | 92 | 19.2 | 1.62E–07 | 1.61E–16 | |
3 | –0.002 | –3.10E–06 | –92 | –19.2 | 1.62E–07 | 1.61E–16 | |
4 | –0.005 | –7.75E–06 | –205 | –42.7 | 1.81E–07 | 1.80E–16 | |
Average:
|
1.73E–07 | 1.71E–16 | |||||
0.14 (20) | 1 | 0.005 | 7.75E–06 | 400 | 83.3 | 9.30E–08 | 9.23E–17 |
2 | 0.002 | 3.10E–06 | 170 | 35.4 | 8.75E–08 | 8.69E–17 | |
3 | –0.002 | –3.10E–06 | –180 | –37.5 | 8.27E–08 | 8.21E–17 | |
4 | –0.005 | –7.75E–06 | –395 | –82.3 | 9.42E–08 | 9.35E–17 | |
Average:
|
8.93E–08 | 8.87E–17 | |||||
0.28 (40) | 1 | 0.005 | 7.75E–06 | 590 | 122.9 | 6.31E–08 | 6.26E–17 |
2 | 0.002 | 3.10E–06 | 245 | 51.0 | 6.07E–08 | 6.03E–17 | |
3 | –0.002 | –3.10E–06 | –240 | –50.0 | 6.20E–08 | 6.15E–17 | |
4 | –0.005 | –7.75E–06 | –600 | –125.0 | 6.20E–08 | 6.15E–17 | |
Average:
|
6.19E–08 | 6.15E–17 | |||||
0.41 (60) | 1 | 0.005 | 7.75E–06 | 720 | 150.0 | 5.17E–08 | 5.13E–17 |
2 | 0.002 | 3.10E–06 | 290 | 60.4 | 5.13E–08 | 5.09E–17 | |
3 | –0.002 | –3.10E–06 | –300 | –62.5 | 4.96E–08 | 4.92E–17 | |
4 | –0.005 | –7.75E–06 | –715 | –149.0 | 5.20E–08 | 5.16E–17 | |
Average:
|
5.12E–08 | 5.08E–17 | |||||
0.55 (80) | 1 | 0.005 | 7.75E–06 | 870 | 181.3 | 4.28E–08 | 4.24E–17 |
2 | 0.002 | 3.10E–06 | 340 | 70.8 | 4.38E–08 | 4.34E–17 | |
3 | –0.002 | –3.10E–06 | –352 | –73.3 | 4.23E–08 | 4.20E–17 | |
4 | –0.005 | –7.75E–06 | –866 | –180.4 | 4.30E–08 | 4.26E–17 | |
Average:
|
4.29E–08 | 4.26E–17 |
Positive values of volumetric flow rate and discharge velocity indicate bottom to top flow through the specimen; negative values indicate top to bottom flow.
Previous | Close | Next | Top of page