Previous   |    Close   |    Next

Table T12. Results of contamination tests using fluorescent microspheres, Site C0017.

Core, section Depth
(mbsf)
PFT
in test vial gas phase
(ppm)
Sample weight
in test vial
(g)
PFT
per g sample
(ppm)
Interior Outer edge Interior Outer edge Interior Outer edge
331-C0017A-      
1H-1 0.65 ND 5.16E–02 1.17 3.38 ND 1.53E–02
1H-5 6.37 ND 4.52E–02 2.47 0.91 ND 4.97E–02
331-C0017B-      
1H-2 10.811 ND 1.61E–01 2.17 1.95 ND 8.26E–02
1H-5 14.802 ND 5.99E–02 3.83 1.78 ND 3.37E–02
331-C0017C-      
1H-2 20.088 ND 4.93E–02 5.21 1.97 ND 2.50E–02
1H-7 26.579 ND 1.71E–03 0.78 1.43 ND 1.20E–03
2H-2 29.95 ND 1.21E–02 4.95 3.08 ND 3.93E–03
331-C0017D-      
1H-3 63.633 2.30E–03 2.03E–02 1.17 2.73 1.97E–03 7.44E–03
1H-5 66.382 5.94E–03 3.23E–03 2.25 2.93 2.64E–03 1.10E–03
1H-6 68.052 ND 4.41E–03 2.56 0.53 ND 8.32E–03
2H-5 74.873 ND 8.23E–03 2.81 3.89 ND 2.12E–03
6X-1 94.96 ND 4.12E–03 3.54 2.22 ND 1.86E–03
7H-4 108.197 3.94E–03 5.99E–03 2.41 4.06 1.63E–03 1.48E–03
9X-8 130.1 6.56E–03 1.37E–02 3.29 4.60 1.99E–03 2.98E–03
10X-4 136.1 3.36E–03 NT 3.77 NT 8.91E–04 NT
11X-1 141.1 2.19E–02 4.93E–02 4.66 2.92 4.70E–03 1.69E–02

PFT = perfluorocarbon tracer. ND = not detected, NT = not tested.