Table T5. Unconfined compressive strength (UCS), Hole C0019E.

Core, section,
interval (cm)
Depth
(mbsf)
Diameter
(mm)
Length
(mm)
Reading
force (N)
Strength
(MPa)
l/d
Length
correction
factor
UCS
(MPa)
343-C0019E-  
7R-2, 35–37 714.49 19.8 20.50 1320.00 4.29 1.04 0.87 3.75
8R-1, 108–110 720.08 19.8 21.50 460.00 1.49 1.09 0.88 1.32
11R-CC, 8–10 780.55 19.8 23.00 1170.00 3.80 1.16 0.89 3.38
13R-1, 26–28 801.26 19.9 14.40 2410.00 7.75 0.72 0.83 6.44
14R-2, 10–12 811.40 19.8 13.80 2820.00 9.16 0.70 0.83 7.57
15R-CC, 3–5 817.74 19.8 14.70 2770.00 9.00 0.74 0.83 7.50
19R-1, 97–99 827.47 19.8 21.30 1200.00 3.90 1.08 0.88 3.43
20R-1, 18–20 831.18 19.8 22.00 1630.00 5.29 1.11 0.88 4.68
21R-1, 19–20 836.69 12.5 18.30 8690.00 70.81 1.46 0.92 65.27

l = length, d = diameter.