Close   |    Next

Table T1. Downhole measurements made by the wireline tool strings during IODP Expedition 340T.

Tool string Tool Measurement Sampling interval
(cm)
Vertical resolution
(cm)
Triple combo LEH-MT Temperature 15 NA
EDTC Total gamma ray 5 and 15 30
HLDS Bulk density 2.5 and 15 38
HRLA Resistivity 15 30
MTT Temperature 15 NA
Sonic LEH-MT Temperature 15 NA
EDTC Total gamma ray 5 and 15 30
DSI Acoustic velocity 15 107
GPIT Tool orientation and acceleration 4 15
Magnetic susceptibility LEH-MT Temperature 15 NA
EDTC Total gamma ray 5 and 15 30
MSS Magnetic susceptibility 2.54 40
Versatile Seismic Imager LEH-MT Temperature 15 NA
VSI One-way acoustic traveltime Stations at 10–20 m NA
EDTC Total gamma ray 5 and 15 30

All tool and tool string names except the MTT and MSS are trademarks of Schlumberger. Sampling interval based on optimal logging speed. Acoustic imaging approximate vertical resolution is at 500 kHz. NA = not applicable. For definitions of tool acronyms, see Table T3.

Close   |    Next   |    Top of page