Table T23. Temperature data, Site U1351. (See table notes.)

Core Tool Depth
CSF-A (m)
Temperature
(°C)
ti
(s)
tf
(s)
tfti
(s)
Reliability
317-U1351A-
4H APCT-3 25.1 11.61 90 734 644 Good
317-U1351B-
10H SET 70.7 9.03 34 167 133 Poor
12H SET 86.2 12.78 52 316 264 Poor
16X SET 123.4 11.51 27 108 81 Poor
42X SET 372.5 15.59 459 689 230 Poor

Notes: Times ti and tf are the initial and final times of the interval, respectively, picked to estimate asymptotic temperature for each data set. Estimated temperatures are considered reliable when the picked interval, tft, is >300 s. APCT-3 = third-generation advanced piston corer temperature tool, SET = Sediment Temperature tool. APCT-3 measurement depth is the bottom of the cored interval. SET measurement depth is the bottom of the last cored interval plus 1 m, the approximate distance the temperature sensor advances beneath the bit.