Table AT38. Event summary of T2P Deployment 17, Hole U1322B, 42.0 mbsf. (See table notes.)
| Event number |
Time (GMT) |
Event description |
|---|---|---|
| 1 | 1839 | Start data logger at 1 Hz |
| 2 | 2010 | T2P on rig floor |
| 3 | 2022 | Start lowering T2P downhole, pumps on |
| 4 | 2029 | Stop at 491 mbsl, pumps off |
| 5 | 2031 | Start lowering probe |
| 6 | 2035 | Stop at 741 mbsl, pumps off |
| 7 | 2037 | Start lowering probe |
| 8 | 2043 | Stop at 1321 mbsl, pumps off |
| 9 | 2046 | Start lowering probe |
| 10 | 2048 | Stop at 1351 mbsl, pumps off |
| 11 | 2050 | Start lowering probe |
| 12 | 2057 | CDS lands in BHA, pumps off |
| 13 | 2057 | Start penetration of T2P into sediment |
| 14 | 2100 | End of T2P penetration, bit on BOH |
| 15 | 2100 | Raise BHA 4.0 m off BOH |
| 16 | 2207 | Pull T2P uphole slowly with wireline |
| 17 | 2210 | Stop at 1321 mbsl, pumps off |
| 18 | 2213 | Pull T2P uphole slowly with wireline |
| 19 | 2219 | Stop at 741 mbsl, pumps off |
| 20 | 2221 | Pull T2P uphole slowly with wireline |
| 21 | 2226 | Stop at 491 mbsl, pumps off |
| 22 | 2228 | Pull T2P uphole slowly with wireline |
| 23 | 2232 | Disconnect wireline from CDS |
| 24 | 2235 | Disconnect CDS from spacer |
| 25 | 2237 | Disconnect spacer from CDS |
| 26 | 2238 | T2P out of pipe |
| 27 | Download data from data logger |
Notes: Measurements taken 28 June 2005. GMT = Greenwich Mean Time, T2P = temperature/dual pressure probe, CDS = colleted delivery system, BHA = bottom-hole assembly, BOH = bottom of hole.
Previous | Close | Next | Top of page