Previous   |   Close   |   Next

Table T17. Downhole measurements made by wireline tool strings, Expedition 317. (See table notes.)

Tool string Tool Measurement Sampling
interval (cm)
Approximate
vertical
resolution (cm)
Triple combination HNGS Spectral gamma ray 15 20–30
GPIT Tool orientation 3.8 15
HLDS Bulk density 2.5 and 15 38
DIT Resistivity 15 240/180/92
APS Porosity 5 and 15 36
Formation MicroScanner-sonic HNGS Spectral gamma ray 15 20–30
GPIT Tool orientation 3.8 15
FMS Microresistivity 0.25 0.5
DSI Acoustic velocity 15 107
Versatile Seismic Imager SGT Total gamma ray 5 and 15 30
VSI Acoustic travel time Stations at 20 m NA

Notes: All tool names are trademarks of Schlumberger. Sampling interval is based on optimal logging speed. NA = not applicable. For definitions of tool acronyms, see Table T18.

Previous   |   Close   |   Next  |  Top of page